1. Error Message
Express5800/R120d-1E, R120d-2E Maintenance Guide
149
Chapter 3 Appendix
(4/6)
BMC Message on Lower LCD Line
Description
Solution
Processor1 Internal Error
Processor2 Internal Error
An internal CPU error (IERR)
occurred.
Sensor Failure Detected.
Abnormality in a sensor was
detected.
SMI timeout
A timeout occurred while
servicing system management
interrupts.
IPMI Watchdog timer timeout
(Power off)
A watchdog timer timeout
occurred.
Node Manager Internal Error
Contact your sales representative.
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash
Erase Error
Node Manager Firmware Flash
Corrupted
Node Manager Firmware Flash
Corrupted
Node Manager can't
communicate BMC
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash
Erase Error
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
Node Manager can't
communicate BMC
Node Manager Manufacturing
Error
Node Manager Persistent
Storage Integrity Error
Abnormality in Node Manager
occurred.
Drive 0 Fault
Drive 1 Fault
Drive 2 Fault
Operation was performed during
Hard Disk Drive failure
Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your sales representative.