1. Installing Internal Optional Devices
Express5800/R110f-1E User’s Guide
60
Chapter 2 Preparations
1.9.3
Installation
Install a DIMM by using the following procedure.
1.
Refer to steps 1 to 4 in
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations.
2.
Lift the duct off the server.
3.
Rotate both levers outward and push the
DIMM straight into the socket.
When a DIMM is inserted into the socket,
the lever automatically closes.
Important
•
Align the notch on the DIMM with the key on the slot.
•
Do not apply too much pressure when you push a DIMM into the socket.
Doing so can damage the socket or terminal part.
4.
Attach the duct.
5.
Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
6.
Confirm that no error messages are displayed in POST screen.
If any error messages are displayed, refer to
Chapter 3 (1. POST Error Message)
in "
Maintenance
Guide
".
7.
Run the SETUP utility, and select
Memory Configuration
and then
Memory Information
from the
Advanced
menu. Make sure the capacity of added DIMM is displayed properly.
Refer to
Chapter 2 (1. System BIOS)
in "
Maintenance Guide
".
8. Select
Memory Configuration
from the
Advanced
menu, and then specify
Yes
for
Memory Retest
.
After that, select
Save Changes and Exit
to reboot.
9.
Set the paging file size to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, refer to
Chapter 1 (7.1 Specifying Memory Dump Settings (Debug Information))
in "
Installation Guide (Windows)
".
For other OS, consult the manual provided with the operation system or contact the store where you
purchased it or your maintenance service company.
Notch
Key