background image

Ჶᩓ

ᩓเȷᩓเdzȸȉƴ᧙Ƣǔදॖʙ᪮Ჸ

Power Supply and Power Cord Use

CAUTION

ᩓเƕ

ON

Ʒ

ƷLJLJӕǓ˄ƚȷӕǓٳƠǛƠƳƍ

Disconnect the power cord(s) before installing or removing the
product in/from the server.

ஜ˳ᘺፗǁƷӕǓ˄ƚȷӕǓٳƠƷᨥǍŴԗᡀೞ֥ƱƷ੗ዓƷᨥƸ࣏ƣ
ɼᩓเƴ੗ዓƠƯƍǔᩓเdzȸȉǛ

AC

dzȳǻȳȈƔǒ৷ƍƯƘƩƞƍŵ

ᩓเdzȸȉƕ

AC

dzȳǻȳȈƴ੗ዓƞǕƨLJLJӕǓ˄ƚȷӕǓٳƠǍ੗ዓ

ǛƢǔƱज़ᩓƢǔƓƦǕƕƋǓLJƢŵ

Make sure to power off the server and disconnect the power cord(s) from 
a power outlet before installing/removing the product in/from the server,
or connecting with the peripheral devices. All voltage is removed only 
when the power cords are unplugged.

ᄊ੷ƠƨDZȸȖȫǛ̅ဇƠƳƍ

Do not use any damaged cable.

DZȸȖȫǛ੗ዓƢǔЭƴdzȍǯǿƕᄊ੷ƠƯƍƨǓŴdzȍǯǿȔȳƕ୺
ƕƬƯƍƨǓŴ൲ǕƨǓƠƯƍƳƍƜƱǛᄩᛐƠƯƘƩƞƍŵᄊ੷Ǎ୺
ƕƬƯƍǔdzȍǯǿƓǑƼ൲ǕƨdzȍǯǿǛ̅ဇƢǔƱǷȧȸȈƴǑǓ
້໎ǛࡽƖឪƜƢƓƦǕƕƋǓLJƢŵ

Make sure the cable condition before connection. Using the damaged 
connector, bent connector pin, or dirty connector may cause a fire due to 
short-circuit.

ƵǕƨ৖ưᩓเdzȸȉǛNjƨƳƍ

Do not hold the power plug with a wet hand.

ஜᙌԼƷӕǓ˄ƚȷӕǓٳƠƷئӳƸŴƵǕƨ৖ưஜ˳ᘺፗƷᩓเdzȸ
ȉƷ৷ƖࠀƠǛƠƳƍưƘƩƞƍŵज़ᩓƢǔƓƦǕƕƋǓLJƢŵ

Do not disconnect/connect the plug while your hands are wet. Failure to 
follow this warning may cause an electric shock.

ᩓเdzȸȉƷDZȸȖȫᢿǛਤƬƯࡽƖ৷ƔƳƍ

Do not pull the cable when disconnecting the power cord.

ஜ˳ᘺፗƷᩓเdzȸȉƷ৷ƖࠀƠƸŴDZȸȖȫᢿǛਤƬƯࡽƬࢌǒƳƍ
ưƘƩƞƍŵDZȸȖȫƕͻLjŴज़ᩓǍ້໎ƷҾ׆ƱƳǓLJƢŵ

When disconnecting the power cord from the server, hold the plug and
pull it straight out. Pulling the cord out by the cable portion could damage 
the cable to result in an electrical shock hazard or a fire.

Ჶᚨፗȷᆆѣȷ̬ሥȷ੗ዓƴ᧙Ƣǔදॖʙ᪮Ჸ

Installation, Relocation, Storage, and Connection

CAUTION

ȗȩǰǛࠀƠᡂǜƩLJLJǤȳǿȕǧȸǹDZȸȖȫƷӕǓ˄ƚǍӕǓٳƠ
ǛƠƳƍ

Do not connect any interface cable with the power cord of the 
server plugged to a power source.

ǤȳǿȕǧȸǹDZȸȖȫƷӕǓ˄ƚᲩӕǓٳƠƸஜ˳ᘺፗƷᩓเdzȸȉ
ǛdzȳǻȳȈƔǒ৷ƍƯᘍƬƯƘƩƞƍŵƨƱƑᩓเǛ

OFF

ƴƠƯNjᩓ

เdzȸȉǛ੗ዓƠƨLJLJDZȸȖȫǍdzȍǯǿƴᚑǔƱज़ᩓƠƨǓŴ
ǷȧȸȈƴǑǔ້໎ǛឪƜƠƨǓƢǔƜƱƕƋǓLJƢŵ

Make sure to power off the server and unplug the power cord from a 
power outlet before connecting/disconnecting any interface cable to/from 
the server.    If the server is off-powered but its power cord is plugged to 
a power source, touching a cable or connector may cause an electric 
shock or a fire resulted from a short circuit.

ਦܭˌٳƷǤȳǿȕǧȸǹDZȸȖȫǛ̅ဇƠƳƍ

Do not use any unauthorized interface cable.

ǤȳǿȕǧȸǹDZȸȖȫƸŴ

NEC

ƕਦܭƢǔNjƷǛ̅ဇƠŴ੗ዓƢǔᘺ

ፗǍdzȍǯǿǛᄩᛐƠƨɥư੗ዓƠƯƘƩƞƍŵਦܭˌٳƷDZȸȖȫǛ
̅ဇƠƨǓŴ੗ዓέǛᛚƬƨǓƢǔƱŴǷȧȸȈƴǑǓ້໎ǛឪƜƢƜ
ƱƕƋǓLJƢŵ
LJƨŴǤȳǿȕǧȸǹDZȸȖȫƷӕǓৢƍǍ੗ዓƴƭƍƯഏƷදॖǛƓ
ܣǓƘƩƞƍŵ

„

DZȸȖȫǛ៊LJƳƍŵ

„

DZȸȖȫƷɥƴNjƷǛ᠍ƤƳƍŵ

„

DZȸȖȫƷ੗ዓƕǏǔǜƩLJLJ̅ဇƠƳƍŵ

„

ᄊ੷ƠƨDZȸȖȫǛ̅ဇƠƳƍŵ

„

ᄊ੷ƠƨDZȸȖȫdzȍǯǿǛ̅ဇƠƳƍŵ

„

ȍǸഥNJƳƲƷȭȃǯǛᄩܱƴᘍƬƯƘƩƞƍŵ

Use only interface cables authorized by NEC and locate a proper device 
and connector before connecting a cable. Using an unauthorized cable 
or connecting a cable to an improper destination may cause a short 
circuit, resulting in a fire.
Also, observe the following notes on using and connecting an interface 
cable.

„

Do not step on the cable.

„

Do not place any object on the cable.

„

Do not use the server with loose cable connections.

„

Do not use any damaged cable connector.

„

Make sure the cable is securely locked with screw.

CAUTION

Ᏽ᫢ࣱǬǹƷ܍נƢǔ࿢ؾư̅ဇLJƨƸ̬ሥƠƳƍ

Do not use or store the product in the place where corrosive gases 
exist.

Ᏽ᫢ࣱǬǹᲢʚᣠ҄ᄑ᰾Ŵᄑ҄൦እŴʚᣠ҄ᆷእŴطእŴǢȳȢȋǢŴ
ǪǾȳƳƲᲣƷ܍נƢǔ࿢ؾƴᚨፗƠŴ̅ဇƠƳƍưƘƩƞƍŵ
LJƨŴDŽƜǓǍᆰൢɶƴᏵ᫢Ǜ̟ᡶƢǔ঺ЎᲢط҄ȊȈȪǦȠǍᄑ᰾Ƴ
ƲᲣǍݰᩓࣱƷ᣿ޓƳƲƕԃLJǕƯƍǔ࿢ؾǁNjᚨፗƠƳƍưƘƩƞƍŵ
ᘺፗϋᢿƷȗȪȳȈெƕᏵ᫢ƠŴ૏ᨦƓǑƼႆ໺ȷႆ້ƷҾ׆ƱƳǔƓ
ƦǕƕƋǓLJƢŵNjƠƝ̅ဇƷ࿢ؾưɥᚡƷွƍƕƋǔئӳƸŴᝤ٥ࡃ
LJƨƸ̬ܣǵȸȓǹ˟ᅈƴƝႻᛩƘƩƞƍŵ

Make sure not to locate or use the server in the place where corrosive 
gases (sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, 
ammonia, ozone, etc) exist.
Also, do not install it in the environment where the air (or dust) includes 
components accelerating corrosion (ex. sulfur, sodium chloride) or 
conductive metals. There is a risk of a fire due to corrosion and shorts of 
an internal printed board.
Consult with your service representative for the location appropriate to 
the server.

᭗ภදॖ

Avoid installation in extreme temperature conditions.

ஜ˳ᘺፗƷᩓเǛ

OFF

ƴƠƨႺࢸƸŴϋᔺ׹ƷȏȸȉȇǣǹǯȉȩǤȖ

ƳƲǛƸơNJᘺፗϋƷᢿԼƕ᭗ภƴƳƬƯƍLJƢŵҗЎƴϬNJƨƜƱǛ
ᄩᛐƠƯƔǒӕǓ˄ƚ

/

ӕǓٳƠǛᘍƬƯƘƩƞƍŵ

Immediately after the server is powered off, its internal components such 
as hard disk drives are very hot. Leave the server until its internal 
components fully cool down before installing/removing any component.

ᲶƓ৖λǕƴ᧙Ƣǔදॖʙ

᪮Ჸ

Cleaning and Working with the Product

WARNING

ᐯЎưЎᚐȷ̲ྸȷોᡯƸƠƳƍ

Do not disassemble, repair, or alter the server.

ஜᙌԼƷЎᚐǍŴ̲ྸȷોᡯƸዌݣƴƠƳƍưƘƩƞƍŵᘺፗƕദࠝƴ
ѣ˺ƠƳƘƳǔƹƔǓưƳƘŴज़ᩓǍ້໎ƷүᨖƕƋǓLJƢŵ

Never attempt to disassemble, repair, or alter the product on any 
occasion. Failure to follow this instruction may cause an electric shock or 
fire as well as malfunctions of the product.

ȗȩǰǛࠀƠᡂǜƩLJLJӕǓৢǘƳƍ

.

Disconnect the power plug before accessing inside the server.

Ɠ৖λǕƸŴஜ˳ᘺፗƷᩓเǛ

OFF

ƴƠƯŴᩓเdzȸȉǛ

AC

dzȳǻȳȈ

Ɣǒ৷ƍƯƘƩƞƍŵƨƱƑᩓเǛ

OFF

ƴƠƯNjŴᩓเdzȸȉǛ੗ዓƠ

ƨLJLJᘺፗϋƷᢿԼƴᚑǔƱज़ᩓƢǔƓƦǕƕƋǓLJƢŵ

Make sure to power off the server and disconnect the power plug from a 
AC outlet before accessing inside the server. Touching any internal 
device of the server with its power cord connected to a power source 
may cause an electric shock even if the server is off-powered.

CAUTION

ɶᡦҞᇢƴӕǓ˄ƚƳƍ

Make sure to complete installation.

DC

DZȸȖȫǍǤȳǿȕǧȸǹDZȸȖȫƸᄩܱƴӕǓ˄ƚƯƘƩƞƍŵɶ

ᡦҞᇢƴӕǓ˄ƚǔƱ੗ᚑɧᑣǛឪƜƠŴႆ໺Ǎႆ້ƷҾ׆ƱƳǔƓƦ
ǕƕƋǓLJƢŵ

Always connect the DC cable and/or interface cable firmly. An 
incompletely connected cable may cause a contact failure, resulting in 
smoking or fire.

ᲶᢃဇɶƷදॖʙ᪮Ჸ

During Operation

CAUTION

ᩑƕƳƬƨǒᚑǒƳƍ

Avoid contact with the server during thunderstorms.

ᩑƕᯚǓƩƠƨǒŴஜᙌԼϋᔺƷஜ˳ᘺፗƴƸŴᚑǕƳƍưƘƩƞƍŵ
ज़ᩓƢǔƓƦǕƕƋǓLJƢŵ

If it starts thundering, do not touch any part of the server containing the 
product. Failure to follow this warning may cause an electric shock.

ȚȃȈǛᡈƮƚƳƍ

Keep animals away from the server.

ஜᙌԼƕϋᔺƞǕƨஜ˳ᘺፗƴȚȃȈƳƲƷဃƖཋǛᡈƮƚƳƍưƘƩ
ƞƍŵ੎ඟཋǍ˳ൗƕᘺፗϋᢿƴλƬƯ້໎Ǎज़ᩓƷҾ׆ƱƳǓLJƢŵ

Keep animals away from the server containing the product.
Pet's discharges or fur may enter the server and cause a fire or electric
shock.

Summary of Contents for N8103-205

Page 1: ...erver And read this Notes on Use carefully before handling this product See a user s guide in http www nec com express for the detailed function of this product Ɲදॖ Notes 1 ஜ ƷϋܾƷɟᢿLJƨƸμᢿǛ ૺ ƢǔƜƱƸᅠഥƞǕƯƍLJƢŵ 2 ஜ Ʒϋܾƴ᧙ƠƯƸ ݩ ஹʖԓƳƠƴ ƢǔƜƱƕƋǓLJƢŵ 3 NEC ƷᚩӧƳƘᙐᙌȷો ƳƲǛᘍƏƜƱƸưƖLJƤǜŵ 4 ஜ ƸϋܾƴƭƍƯɢμǛ ƠƯ ƍƨƠLJƠƨƕŴɢɟƝɧ ݙ ƳໜǍᛚǓŴᚡ NjǕƳƲƓൢƮƖƷƜƱƕƋǓLJƠƨ ǒŴƓᝰƍ൭NJƷᝤ٥ࡃƴƝᡲዂƘƩƞƍŵ 5 ᢃဇƠƨኽௐƷࢨ ƴƭƍƯƸ 4 ƴƔƔǘǒƣᝧ Ǜ ƍƔƶLJƢƷưƝʕ১ƘƩƞƍŵ 6 ᓳɠŴʏ...

Page 2: ...ith wet hand Otherwise an electric shock may be caused ᘍໝƷࢍС Mandatory Action ᩓเdzȸȉǛdzȳǻȳȈƔǒ ƍƯƘƩƞƍŵ Ǎज़ᩓƷƓƦǕƕƋǓ LJƢŵ Unplug the power cord of the server Otherwise an electric shock or fire may be caused ཎ ܭ ƠƳƍɟᑍႎƳ ဇᎍƷᘍໝǛਦᅆƠLJƢŵᛟଢƴࢼƬƨદ ǛƠƯ ƘƩƞƍŵ Indicates a mandatory action that cannot be specifically identified Make sure to follow the instruction Ᏻ ୖࡢࡈὀព Safety Indications ஜᙌԼǛ ܤ μƴƓ ƍƍƨƩƘƨNJƴŴƜƜưᛟଢƢ...

Page 3: ...o not place any object on the cable Do not use the server with loose cable connections Do not use any damaged cable connector Make sure the cable is securely locked with screw CAUTION Ᏽ ࣱǬǹƷ נ Ƣǔ ؾ ư ဇLJƨƸ ሥƠƳƍ Do not use or store the product in the place where corrosive gases exist Ᏽ ࣱǬǹᲢʚᣠ ᄑ Ŵᄑ ൦እŴʚᣠ ᆷእŴ ط እŴǢȳȢȋǢŴ ǪǾȳƳƲᲣƷ נ Ƣǔ ؾ ƴᚨፗƠŴ ဇƠƳƍưƘƩƞƍŵ LJƨŴDŽƜǓǍᆰൢɶƴᏵ Ǜ ᡶƢǔ ЎᲢ ط ȊȈȪǦȠǍᄑ Ƴ ƲᲣ Ǎ ݰ ᩓࣱƷ ޓ ƳƲƕ...

Page 4: ... type de risque Exemple Risque de décharge Électrique Action qui Est interdite Ce symbole signale des actions qui sont interdites Une image dans le symbole illustre une action interdite particulière Exemple Ne démontez pas Action obligatoire Ce symbole signale des actions qui sont obligatoires Une image dans le symbole illustre une action obligatoire pour éviter un risque particulier Exemple Décon...

Page 5: ...ound to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communicat...

Page 6: ...ntative NEC assumes no liability for data leakage if the product is transferred to third party without erasing the data ǽȕȈǦǧǢƴ᧙ƠƯƸŴ ᜯบƠƨ ƸɟЏƷᙐᙌཋǛ ஊƠƳƍưƘƩƞƍŵ LJƨŴ ǤȳǹȈȸ ȫƠƨᘺፗƔǒЪᨊƠƨࢸŴᜯบƠƯƘƩƞƍŵ To transfer or sell any software application that comes with the product to a third party the following requirements must be satisfied All provided software applications must be transferred and no backup copie...

Page 7: ...xavalent chromium Cr 6 ከ Ɽ Polybrominated biphenyls PBB ከ Ɽ憁 Polybrominated biphenyl ethers PBDE 㟁Ꮚ ືඖ Passive Components ۑ ۑ ۑ ۑ ۑ 㟁 ᯈ Printed Circuit Board ۑ ۑ ۑ ۑ ۑ ۑ 㐃᥋ჾ Connector Mechanical ۑ ۑ ۑ ۑ ۑ ۑ 㧓㟁 Active Devices ۑ ۑ ۑ ۑ ۑ ۑ ഛ 1 ࠦ ฟ0 1 wt ࠧཬࠦ ฟ0 01 wt ࠧಀᣦ㝈 அⓒศẚྵ㔞 ฟⓒศẚྵ㔞ᇶ ࠋ Note 1㸸 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance ex...

Reviews: