59
10.
Close the lever that was opened in Step 7 to fix the BBU.
11.
Install the disk array controller in the PCI (PCI Express) slot of the server, and
secure it with screws.
12.
Connect all the cables to the disk array controller as before.
13.
Install the removed side cover and power cords to recover the original state. Turn
on the power of the server.
14.
After OS is booted, check whether the BBU is recognized correctly. For the
checking procedure, see "2. Checking by Utility" in "Chapter 2 Installation of
BBU."
Notice
The battery cell you have purchased is not charged at all. For such
battery cell, the [Current Write Policy] in [Properties] of [Logical] tab is
indicated as "Write Through" on MSM.
You can check the charged status of battery cell by selecting [Relative
State of Charge] or [Absolute State of Charge] in [Physical] tab
[Properties] on MSM.
Check
The battery cell is recyclable. Contact your service representative for the
recycle.
Disk array controller
New BBU
Old BBU
8
10
7
9
10
7