CHAPTER 2 INSTALLATION
External TAS Indicator (DK/MP)
NEAX2000 IVS
2
Installation Procedure Manual
Page 170
ND-70928 (E), Issue 1.0
(2)
MDF Cross Connection
•
When using a TAS Indicator with a Battery
Figure 2-80 MDF Cross Connection for TAS Indicator with Battery
29
K7
29
4
K6
4
28
K5
28
3
K4
3
27
K3
27
26
K1
26
2
1
1
K0
26
K1
2
K2
27
K3
3
K4
28
K5
4
K6
29
K7
LTC0 (P)
26
K1
1
K0
27
K3
2
K2
28
K5
3
K4
29
K7
4
K6
LEN000
LEN002
LTC0 (J)
MDF
K0
1
K2
2
LEN000
PIM0
P
PN-DK00
LT00
LTC0
J
LEN002
TAS INDICATOR
WITH BATTERY
IND
PZ-PW121
–
27V
G
K0