CHAPTER 2 INSTALLATION
Power Failure Transfer (AUC)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 183
(2)
MDF Cross Connection
Figure 2-90 MDF Cross Connection for PFT (AUC) (1 of 2)
NOTE 1: The No. 2 and No. 3 circuit in the PN-4COT card cannot be used for PFT function.
NOTE 2: When using Ground Start trunks with PFT function, the single line stations must have
a ground sending button and a ground lead must be run to the station.
1
26
2
27
3
28
4
29
9
34
10
35
C.O.R0
C.O.T0
C.O.R1
C.O.T1
PN-4COT
1
26
2
27
3
28
4
29
TO
STATION
Sta. R0
Sta. T0
Sta. R1
Sta. T1
MDF
PIM0
PN-AUC
LT00
9
34
10
35
J
P
LTC0
4Q-TW-0.3 CONN CA
LT01
LEN000 (No. 0)
LEN001 (No. 1)
CN1
04
03
02
01
CN1
04
03
02
01
LEN008 (No. 0)
LEN009 (No. 1)
Ring
TO
STATION
Tip
Tip
Ring
TO
C.O. LINE
TO
C.O. LINE
Ring
Ring
Tip
Tip