To reset CAT mode:
While “COMMAND = -” is displayed on the LCD:
1.
Lift the handset (off hook)
-
SPKR/Speaker lamp turns off.
2.
Restore the handset (on hook)
-
CNF/Conf, FNC/Feature lamps turn off.
-
LCD returns to clock.
MAT
Refer to the MATWorX User Guide.
Cofirming Lamp Indication
After system data entry, confirm proper operation of the system using indicator lamps.
• RUN Lamp Flashing (120 IPM)
Check that the RUN lamps of PN-CP14 card and other application circuit cards are flashing.
• ON Lamps of All PZ-PW121 Cards Lightning
Check that the ON lamps of all the PZ-PW121 cards are lightning and their MJ/MN lamps
have gone out.
• BL Lamps Gone Out
Check that the BL lamps of all the line/trunk circuit cards have gone out. If BL lamps are
flashing, it means that the corresponding circuit is in make-busy state or the system data for
this card is not assigned.