CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-A (DBM)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 227
Lamp Indications
Switch Settings
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally.
WE
Red
Not used
L0-L3
Green
Second data setting value for CMD001 > 250
0
1 (Port 0)-3 (Port 2)
L3
Indication of transmitting
status of Port 0
Indication of CTS signal status on
Port 0-2
L2
Indication of transmitting
status of Port 1
Indication of DCD signal status on
Port 0-2
L1
Indication of transmitting
status of Port 2
Indication of TXD signal status on
Port 0-2
L0
Indication of transmitting
status of Port 3
Indication of RXD signal status on
Port 0-2
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
4-F
Set the switch to match the AP Number (04-15) to
be set by CM05.
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
(Continued)
F
4
AP No.
04 05 06 07 08 09 10 11 12 13 14 15
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN