CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS
2
Installation Procedure Manual
Page 232
ND-70928 (E), Issue 1.0
SW2 (DIP SW)
1
NOTE 3
ON
Sets No. 3 Port forcibly in a state
which DSR signal is always pro-
vided.
OFF
Receives DSR signal from the DCE
on No. 3 Port.
2
ON
Enables the receive clock from the
DCE (Modem) when No. 1 Port is
synchronous. (Clock is received at
the RXC terminal)
OFF
• Uses internal clock as the receive
clock when No. 1 Port is synchro-
nous.
• When No. 1 Port is asynchronous.
3
ON
Enables transmit clock from the
DCE (Modem) when No. 1 Port is
synchronous. (Clock is received at
the TXC (2) terminal.)
OFF
• Uses internal clock as the send
clock when No. 1 Port is synchro-
nous.
• When No. 1 Port is asynchronous.
4
ON
Transmit the send clock from the
DTE (this card) when No. 1 Port is
synchronous. (Clock is transmitted
from the TXC (1) terminal)
OFF
• Not transmit the send clock from
the DTE (this card) when No. 1
Port is synchronous.
• When No. 1 Port is asynchronous.
5
ON
When No. 1 Port is asynchronous.
OFF
When No. 1 Port is synchronous.
(Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4 5 6 7 8
ON