CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS
2
Installation Procedure Manual
Page 246
ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
SW11 (DIP SW)
1
For normal operation
OFF
Not used
2
NOTE 3
NOTE 4
ON
Output clock signals according to
the switch setting of SW11-3.
OFF
Do not output clock signals.
3
NOTE 3
NOTE 4
ON
Output clock signals to PLO 0 of MP.
OFF
Output clock signals to PLO 1 of MP.
4
ON
AP No. 04-15
OFF
AP No. 20-31
(Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON