CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAID (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 269
NOTE 3: When clock source office signal is supplied via the line between the main site and the
remote site, set the SW1-1 and SW1-2 as the following table. In this case, DAID cards
(DAID0, DAID1) must be mounted in PIM0.
NOTE 4: The time slot number 0 and 28 (TS0/28) cannot be used for control signal.
NOTE 5: This setting must be identical with the opposite DAIE card.
CONDITIONS
DAID0
DAID1
DAID2
REMARKS
SW
1-1
SW
1-2
SW
1-1
SW
1-2
SW
1-1
SW
1-2
One DAID card
is provided.
ON
OFF
–
–
–
–
The clock signal is sent
to PLO0 of MP card via
supply route 0 (DAID0).
Two or three
DAID cards are
provided.
ON
OFF
OFF
ON
OFF
OFF
The clock signal supply
route is automatically
changed to the route 1
(DAID1), if a transmis-
sion line failure occurs
on the supply route 0.