CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIE (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 273
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
NOTE 2: The time slot number 0 and 28 (TS0/28) cannot be used for control signal.
NOTE 3: This setting must be identical with the opposite DAID card.
SW3 (DIP SW)
1
Always set to ON
2
Always set to ON
3
Always set to ON
4
Always set to OFF
JPS (Jumper pin)
Balanced transmission: 120 ohms
(For twisted-pair cable)
Left
TA is grounded on the transmission
line: 75 ohms (For coaxial cable)
JPR (Jumper pin)
Right
RA is grounded on the transmission
line: 75 ohms (For coaxial cable)
Balanced transmission: 120 ohms
(For twisted-pair cable)
E1Z (Jumper pin)
Right
Line impedance: 75 ohms (For coax-
ial cable)
Line impedance:
120 ohms (For twisted-pair cable)
SRT (Jumper pin)
Right
Line impedance:
75 ohms (For coaxial cable)
Line impedance:
120 ohms (For twisted-pair cable)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
ON
ON
OFF
Right
Left
Left