CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIF (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
Page 276
ND-70928 (E), Issue 1.0
SW2 (DIP SW)
1
ON
Control channel signaling data
transmission speed: 48kbps
Control channel signaling data
transmission speed: 64kbps
2
ON
CRC Synchronization Detection
Timer is provided.
CRC Synchronization Detection
Timer is not provided.
3
ON
CRC4 Check is provided.
CRC4 Check is not provided.
4
Not used
5
Not used
6
Not used
7
Not used
8
Not used
(Continued)
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4 5 6 7 8
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF