CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-24DTA-C (DTI)
NEAX2000 IVS
2
Installation Procedure Manual
Page 282
ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION-
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
SW1
(Piano Key SW)
NOTE 4
1
Not used
2
Not used
3
Not used
4
ON
AP No. 04-15
OFF
AP No. 20-31
JPR0 (Jumper pin)
UP
Neutral grounding on the receiving
line is provided.
Neutral grounding on the receiving
line is not provided.
JPR1 (Jumper pin)
Line impedance: 100 ohms
Left
Line impedance: 110 ohms
JPS (Jumper pin)
UP
Neutral grounding on the transmit-
ting line is provided.
Neutral grounding on the transmit-
ting line is not provided.
MAS (Jumper pin)
UP
Clock Source
Clock Receiver
AISS (Jumper pin)
AIS signal is sent out when make-
busy or power on.
DOWN
AIS signal is not sent out when
make-busy or power on.
(Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
4
3
2
1
OFF
ON
OFF
OFF
OFF
DOWN
Right
DOWN
DOWN
UP