CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-24PRTA (PRT)
NEAX2000 IVS
2
Installation Procedure Manual
Page 298
ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
JPR0 (Jumper pin)
UP
Neutral grounding on the receiving
line is provided.
Neutral grounding on the receiving
line is not provided.
JPR1 (Jumper pin)
Line impedance: 100 ohms
Left
Line impedance: 110 ohms
JPS (Jumper pin)
UP
Neutral grounding on the transmit-
ting line is provided.
Neutral grounding on the transmit-
ting line is not provided.
MAS (Jumper pin)
UP
Clock Source
Clock Receiver
AISS (Jumper pin)
AIS signal is sent out when make-
busy or power on.
DOWN
AIS signal is not sent out when
make-busy or power on.
(Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
DOWN
Right
DOWN
DOWN
UP