CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2CSIA-A (CSI)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 343
Lamp Indications
LAMP
NAME
COLOR
FUNCTION
OPE
Green
Remains lit when the corresponding circuit is in use.
LB
Red
Remains lit when a loop-back is in progress.
B13
Red
Not used (Flash [60 IPM])
B12
Red
B channel status
ON
: B2 channel of the No. 1 circuit is in use.
OFF
: B2 channel of the No. 1 circuit is idle.
Flash (60 IPM) : CS is not connected to the No. 1 circuit.
CS is in make-busy status.
B11
Red
B channel status
ON
: B1 channel of the No. 1 circuit is in use.
OFF
: B1 channel of the No. 1 circuit is idle.
Flash (60 IPM) : CS is not connected to the No. 1 circuit.
CS is in make-busy status.
B10
Red
B channel status
ON
: B0 channel of the No. 1 circuit is in use.
OFF
: B0 channel of the No. 1 circuit is idle.
Flash (60 IPM) : CS is not connected to the No. 1 circuit.
CS is in make-busy status.
B03
Red
Not used (Flash [60 IPM])
B02
Red
B channel status
ON
: B2 channel of the No. 0 circuit is in use.
OFF
: B2 channel of the No. 0 circuit is idle.
Flash (60 IPM) : CS is not connected to the No. 0 circuit.
CS is in make-busy status.
B01
Red
B channel status
ON
: B1 channel of the No. 0 circuit is in use.
OFF
: B1 channel of the No. 0 circuit is idle.
Flash (60 IPM) : CS is not connected to the No. 0 circuit.
CS is in make-busy status.
(Continued)