CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-M03 (M03)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 375
Switch Settings
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE:
The JP1A and JP1B must be set to the same position each other.
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SW0 (DIP SW)
1
Always set to OFF
2
Not used
JP1A (Jumper pin)
NOTE
TXC(2) signal is sent out.
Left
TXC(2) signal is inputted.
JP1B (Jumper pin)
NOTE
TXC(2) signal is sent out.
Left
TXC(2) signal is inputted.
OPSD
(Jumper pin)
Right
Set the function of extending dis-
tance for TXD signal.
Cancel the function of extending
distance for TXD signal.
OPRS
(Jumper pin)
Right
Set the function of extending dis-
tance for RTS signal.
Cancel the function of extending
distance for RTS signal.
OPER
(Jumper pin)
Right
Set the function of extending dis-
tance for DTR signal.
Cancel the function of extending
distance for DTR signal.
1
2
ON
OFF
OFF
Right
Right
Left
Left
Left