CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-M10 (M10)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 377
Switch Settings
NOTE 1: Set the groove on the switch to the desired position
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
JP0, 1
(Jumper pin)
UP
When connected to E1 (2M) Digital
Trunk Interface.
DOWN
When connected to T1 (1.5M) Digi-
tal Trunk Interface.
JP2 (Jumper pin)
Right
Line code: B8ZS* is provided
(For T1 interface)
*B8ZS: Bipolar Eight zero Substitu-
tion
Left
Line code: B8ZS* is not provide
(For T1 interface)
*B8ZS: Bipolar Eight zero Substitu-
tion
JP3 (Jumper pin)
Right
When connected to E1 (2M) Digital
Trunk Interface.
Left
When connected to T1 (1.5M) Digi-
tal Trunk Interface.
JP4 (Jumper pin)
UP
When connected to E1 (2M) Digital
Trunk Interface.
DOWN
When connected to T1 (1.5M) Digi-
tal Trunk Interface.