CHAPTER 1 GENERAL INFORMATION
Line Conditions of Each Terminal
NEAX2000 IVS
2
Installation Procedure Manual
Page 26
ND-70928 (E), Issue 1.0
LINE CONDITIONS OF EACH TERMINAL
The cable length between the DLC card and terminal varies depending on the type of terminal.
This table shows the line conditions of each D
term
, DSS/BLF Console, and Attendant Console.
Table 1-6 Line Conditions of Each Terminal
TERMINAL TYPE
CARD TYPE
CABLE LENGTH*
(Cable 0.5
φ
/24 AWG)
REMARKS
D
term
75 (Series E)
(8 button)
PN-8DLCL/8DLCP
(STANDARD)
984 ft.
(300 m)
NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)
984 ft.
[3937 ft.
(300 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft.
[3937 ft.
(850 m)
(1200 m)]
D
term
75 (Series E)
(16 button)
PN-8DLCL/8DLCP
(STANDARD)
656 ft.
(200 m)
NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)
656 ft.
[3937 ft.
(200 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft.
[3937 ft.
(850 m)
(1200 m)]
D
term
75 (Series E)
(32 button)
PN-8DLCL/8DLCP
(STANDARD)
656 ft.
(200 m)
NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)
656 ft.
[3937 ft.
(200 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft.
[3937 ft.
(850 m)
(1200 m)]
*The value in brackets [ ] shows the cable length when local power is supplied.