CHAPTER 1 GENERAL INFORMATION
Line Conditions of Each Terminal
NEAX2000 IVS
2
Installation Procedure Manual
Page 28
ND-70928 (E), Issue 1.0
NOTE 1: When using PN-8DLCL or PN-8DLCP card, it is not available long line function, even
if D
term
is equipped with Long Line Adapter.
NOTE 2: The DSS/BLF Console requires local AC/DC power supply.
SN708/709/712
ATTCON
(2-wire type ATTCON)
PN-8DLCL/8DLCP
(STANDARD)
984 ft.
(300 m)
NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)
984 ft.
[3937 ft.
(300 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft.
[3937 ft.
(850 m)
(1200 m)]
SN716 DESKCON
PN-8DLCL/8DLCP
and
PN-PW00 or
AC Adapter
1000 ft.
(304 m)
PN-4DLCM/4DLCQ
and
PN-PW00 or
AC Adapter
1500 ft.
(457 m)
Table 1-6 Line Conditions of Each Terminal (Continued)
TERMINAL TYPE
CARD TYPE
CABLE LENGTH*
(Cable 0.5
φ
/24 AWG)
REMARKS
*The value in brackets [ ] shows the cable length when local power is supplied.