CHAPTER 2 INSTALLATION
Turning Power ON
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 43
Turning Power ON
(1)
Check the switch position of each PZ-PW121 card before turning power on.
• Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for
each country (AC120V or AC240V).
• Make sure that the battery mode selector switch is positioned as shown below to meet the
kind of battery:
(2)
Turn the SW1 switches of all the PZ-PW121 cards to ON. First, turn ON PIM1 to PIM7.
Then, turn ON PIM0 last of all.
CAUTION
1. When the operating power is being supplied to the PZ-PW121 card, do not plug/unplug this
circuit card into/from its mounting slot.
2. When the system is configured with two or more PIMs, the BUS cable provides gang control
for the PZ-PW121 card of PIM0 and other PIMs. Therefore, if the power of PIM0 is off, no
power is supplied to the whole system even when the power switch(es) of other PIMs are
left on. Note, however, that the battery continues to charge even under these circumstances.
3. Do not turn off the PZ-PW121 card on PIM1 to PIM7 when the system is operating.
SW
240V
100V/120V
ON
OFF
12
SW101
1 : Not used
2 : ON (SEAL/FLOAT2)
OFF (OPEN/FLOAT1)