CHAPTER 2 INSTALLATION
Wiring AC Cable to Terminals
NEAX2000 IVS
2
Installation Procedure Manual
Page 50
ND-70928 (E), Issue 1.0
WIRING AC CABLE TO TERMINALS
There are two kinds of AC cable : AC CORD-D For Stationary Equipment/Fixed Equipment (For
Other Countries)
: Installation Cable For Fixed Equipment (For North America/
Australia)
Using AC CORD-D
(1)
Take the AC CORD-D out of the hole on the left side of the BASE, then secure the code to
the BASE with the cord bush.
NOTE:
Cord bush is attached to the AC CORD-D.
(2)
Wire the AC CORD-D and the FG cable to the FG, NEUTRAL, LINE and Ground terminals
on the BASE.
(3)
Wire the AC CORD-B to the FG, NEUTRAL and LINE terminals on the BASE.
Figure 2-3 Wiring AC CORD to Terminals
NOTE:
Cable colors in the parentheses are for Australia.
FG CABLE
(GREEN)
HOW TO SECURE CABLES TO TERMINAL BLOCK
INSERT A SCREW DRIVER INTO THE INSIDE HOLE OF TERMINAL BLOCK.
PULL DOWN THE SCREW DRIVER TOWARD INSIDE AND OPEN THE METAL PLATE.
INSERT A POWER CABLE INTO THE OUTSIDE HOLE OF TERMINAL BLOCK.
REMOVE THE SCREW DRIVER.
1
1
2
2
3
3
4
4
AC CORD-B
AC CORD-D
TO
120V/240V
AC POWER
SOURCE
TO CN1 on
PZ-PW121 in PIM
FG
NEUTRAL
LINE
TERMINAL
BLOCKS
GREEN
(GREEN/YELLOW)
BLACK (BROWN)
BLACK (BROWN)
WHITE (BLUE)
GREEN
(GREEN/YELLOW)
WHITE (BLUE)
BASE
FRONT