CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN Terminal Data Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 109
(3)
Direct In Termination (DIT)
When the ISDN Terminal station number is assigned as the destination of DIT, the system
connects the call with the specified ISDN Terminal or TA on the same bus (2B + D).
In addition to the programming of
"Point-to-Multipoint Connection" on Page 105
, do the
following programming:
DESCRIPTION
DATA
Assign the data for DIT to the trunk
numbers assigned by CM07.
•
•
•
•
(1)
(2)
YY=02 Day Mode
YY=03 Night Mode
YY=40 Mode A
YY=41 Mode B
000-255: Trunk No. assigned by CM07
YY=01
04: Direct-In Termination
Assign the ISDN Terminal station number
to be terminated by Direct In Termination.
•
•
•
•
(1)
(2)
YY=04 Day Mode
YY=05 Night Mode
YY=42 Mode A
YY=43 Mode B
000-255: Trunk No. assigned by CM07
YY=01
X-XXXXXXXX: ISDN Terminal Station
No.
ISDN
ISDN Terminal
Station No. 407
ISDN Terminal
Station No. 400
ISDN Line
Station No. 300
ILC
TRK
PBX
214-555-7881
(Office No.)
START
CM30
END
Summary of Contents for NEAX 2000IVS2