CHAPTER 3 SYSTEM DATA PROGRAMMING
Event Based CCIS Programming
• To provide Verification of Connection for Event Based CCIS, do the following programming.
The following data must be set on the opposite PBX identically.
See also the data setting example on the following pages.
NOTE 1: This feature is available only for the connection between the NEAX2000 IVS
2
/7400ICS
M100MX’s. The same programming must be set on the opposite office.
NOTE 2: This feature is available for installations consisting of PRI to PRI or PRI to BRI. Do not
use for BRI to BRI.
DESCRIPTION
DATA
Provide Verification of Connection to the
Mate-Side trunk route for the voice
channels and the common signaling
channel.
•
(1)
(2)
YYY=152
00-63: Trunk Route No. of Mate-Side
Trunk for voice channels and
common signaling channel
0: To provide
Assign the ISDN subscriber number of
own office for the voice channel route and
the common signaling channel route.
This number is sent and verified with the
number which is set by CM72 on the
opposite office.
•
(1)
(2)
YY=06
000-255: Trunk No. of Mate-Side Trunk
for voice channels and
common signaling channel
X...XXX: Subscriber No. of ISDN line
for voice channels and
common signaling channel
(Max. 16 digits)
Assign the abbreviated codes for
terminating number of the opposite office.
The terminating number and its memory
allocation should be assigned by CM71,
CM72.
•
(1)
(2)
YY=40
00-63: Trunk Route No. of Mate-Side
Trunk for voice channels and
common signaling channel
00-31
: Abbreviated Codes
Assign the memory allocation to store the
terminating number of the opposite office.
(1)
(2)
66
XXX YYY
XXX: 000-299: First Memory Slot No.
YYY: 001-016: Number of Memory Slot
allocated
Set the stored number (terminating
number of the opposite office: access
code for ISDN line + ISDN subscriber
number) to the Memory Slot number
allocated by CM71.
NOTE: The data set by CM35 YY=40,
CM71>66, and CM72 is used to
verify the terminating number sent
from the opposite office.
•
(1)
(2)
Y=0
000-299: Memory Slot No.
Stored No. XXXX + , + YYY...
XXXX: Access Code for ISDN
YYY...: ISDN Subscriber No. of
opposite office (Max. 16 digits)
START
CM35
CM35
CM50
CM71
CM72
END
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70919 E ISSUE 1 STOCK 151988 ISDN System Manual FEBRUARY 2000 NECAmerica Inc ...
Page 11: ...NEAX2000 IVS2 ISDN System Manual Page vi ND 70919 E Issue 1 0 This page is for your notes ...
Page 211: ...NEAX2000 IVS2 ISDN System Manual Page 200 ND 70919 E Issue 1 0 This page is for your notes ...