CHAPTER 4 CIRCUIT CARD INFORMATION
PN-BRTA (BRT)
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 147
Lamp Indications
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally
B1
Green
B1 channel status
ON: Busy
OFF:
Idle
Flash (60 IPM): Make Busy
B2
Green
B2 channel status
ON: Busy
OFF:
Idle
Flash (60 IPM): Make Busy
D
Green
D channel status
ON: Busy
OFF:
Idle
ALM
Red
Transmission line fault status
ON: Line
fault
OFF:
Normal operation