CHAPTER 4 CIRCUIT CARD INFORMATION
PN-2BRTC (BRT)
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 153
Switch Settings
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENS
(Rotary SW)
4-F
Set the switch to match the AP Number (04-31) to
be set by CM05.
0-3
Not used
MB (Toggle SW)
UP
For make-busy
For normal operation
SW0, SW10
(DIP SW)
1
For terminating the transmitting side
of channels B1 and B2 with 100
ohms
OFF
To remove the terminating resistor
on the transmitting side of channels
B1 and B2
2
For terminating the receiving side of
channels B1 and B2 with 100 ohms
OFF
To remove the terminating resistor
on the receiving side of channels B1
and B2
(Continued)
F
4
AP No.
SW11-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW11-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
1 2
ON
ON
ON