CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24PRTA (PRT)
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 169
Lamp Indications
Switch Settings
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally
LC
Green
Remains lit when communications are normally ongoing with the
D channel data links connected
LPB
–
Not used
CRC
Red
Remains lit when detecting Cyclic Redundancy Checking (CRC)
errors
PCM
Red
Remains lit when detecting PCM signal loss
FRM
Red
Remains lit when detecting Frame Alignment signal loss
RMT
Red
Remains lit when receiving Frame Alignment signal loss alarm
from a distant office
AIS
Red
Remains lit when a pattern of consecutive “1” is received.
The distant office transmits this signal for a loop-back test.
BL
Red
B channel status
ON
: More than 10 channels are busy.
OFF
: All channels are idle.
Flash (60 IPM)
: Only one channel is busy.
Flash (120 IPM) : 2 through 10 channels are busy.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
0-3
Not used
4-F
Set the switch to match the AP Number (04-31) to
be set by CM05.
(Continued)
F
4
AP No.
SW1-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70919 E ISSUE 1 STOCK 151988 ISDN System Manual FEBRUARY 2000 NECAmerica Inc ...
Page 11: ...NEAX2000 IVS2 ISDN System Manual Page vi ND 70919 E Issue 1 0 This page is for your notes ...
Page 211: ...NEAX2000 IVS2 ISDN System Manual Page 200 ND 70919 E Issue 1 0 This page is for your notes ...