Interoffice Transmission Line Test
Table 5-4 Alarm Indications on BRT
LED
LED INDICATION
FAULT
NORMAL
FAULT
CAUSE
ACTION
• BRT
RUN
Flash
(120 IPM)
On or Off
Abnormal
operation of BRT
card
Confirm the programming data:
CM05, CM07 YY=02.
Check to see if the SENS
switch is set as per the AP
number (04-15) assigned by
CM05.
Reset the MB switch
(Down
→
Up
→
Down)
If the fault cannot be cleared,
replace the card.
ALM
Off
On
Transmission line
fault
Confirm circuit line status.
Confirm PSTN line status.
• 2BRT
RUN
Flash
(120 IPM)
On or Off
Abnormal
operation of BRT
card
Confirm the programming data:
CM05.
Check to see if the SENSE
switch is set as per the AP
number (04-15, 20-31)
assigned by CM05, CM07
YY=02.
Reset the MB switch
(Down
→
Up
→
Down)
If the fault cannot be cleared,
replace the card.
ALM0
Off
On
No. 0 circuit
transmission line
fault
Confirm No. 0 circuit line
status.
Confirm PSTN line status.
ALM1
Off
On
No. 1 circuit
transmission line
fault
Confirm No. 1 circuit line
status.
Confirm PSTN line status.
1
2
3
4
1
2
1
2
3
4
1
2
1
2
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70919 E ISSUE 1 STOCK 151988 ISDN System Manual FEBRUARY 2000 NECAmerica Inc ...
Page 11: ...NEAX2000 IVS2 ISDN System Manual Page vi ND 70919 E Issue 1 0 This page is for your notes ...
Page 211: ...NEAX2000 IVS2 ISDN System Manual Page 200 ND 70919 E Issue 1 0 This page is for your notes ...