NEAX2000
IVS
2
ISDN System Manual
Page 48
ND-70919 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Installation Procedure for ISDN-PRI
Figure 2-7 Example of Coaxial Cable Connection
COAXIAL CONNECTOR
LTC1 CONNECTOR
17
18
19
20
RA
TA
42
43
44
45
RB
TB
LTC1 (J)
42
43
44
45
RB
TB
17
18
19
20
RA
TA
LTC1 (P)
PIM 0
J
P
CONN
DTI/PRT
AP05
RA
RB
TA
TB
17
42
18
43
17
42
18
43
TO NT1
LTC1
RECEIVE
RCV
SEND
TRS
1
1
2
2