CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-BRI Programming
DESCRIPTION
DATA
Assign trunk route to each ISDN trunk
used for Voice channel (B channel).
NOTE: BRT route must be separated
from analog trunk routes.
•
(1)
(2)
YY=00
000-255: Trunk No. assigned by CM07
YY=01
00-63: Trunk Route
Assign the trunk route data to each ISDN
incoming trunk used for Voice channel
only.
NOTE: If CM35 YYY=143 is set to “1” for
Event Based CCIS, this command
must be set to “18” (ISDN Indial).
•
•
•
•
(1)
(2)
YY=02 Day Mode
YY=03 Night Mode
YY=40 Mode A
YY=41 Mode B
000-255: Trunk No. assigned by CM07
YY=01
04: Direct-In Termination
09: Automated Attendant
14: Termination to Attendant Console
16: Remote Access to System (DISA)
18: ISDN Indial
Assign ISDN Local Office Code Table
number to each ISDN trunk.
•
(1)
(2)
YY=34
000-255: Trunk No. assigned by CM07
YY=02
00-14: Local Office Table No.
15
: Not assigned
Assign trunk route data to the route
number assigned by CM30 YY=00.
•
(1)
(2)
(1)
(2)
YY=00 Kind of Trunk Route
00-63: B channel Trunk Route No.
00: ISDN Trunk
00-63: D channel Trunk Route No.
15
: Not used
•
(1)
(2)
YY=02 Call Direction
00-63: B channel Trunk Route No.
3
•
(1)
(2)
(1)
(2)
YY=04 Answer Signal from distant
office
00-63: B channel Trunk Route No.
2: Answer signal arrives (ISDN Trunk)
00-63: D channel Trunk Route No.
7
: Not used