CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-BRI Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 79
• For originating calls to the ISDN network, do the following programming:
DESCRIPTION
DATA
When the data for CM35 YY=18 is set to
“0” (Received digits conversion is to be
provided), assign the data for interpreting
the digits received.
•
•
•
•
(1)
(2)
YY=01 Day Mode
YY=02 Night Mode
YY=03 Mode A
YY=04 Mode B
000-999: Number Conversion Block
No. assigned by CM76 Y=00
X-XXXXXXXX: Station No. to be
terminated
DXX: Change Terminating System to:
D09: Automated Attendant
D14: Attendant Console
D16: Remote Access to System
(DISA)
DESCRIPTION
DATA
Assign ISDN access code to each trunk
route assigned by CM30 YY=00.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
100-163: Trunk Route 00-63
Specify the timing start when making an
ISDN call from an attendant.
(1)
(2)
403
0
: Not available
1
: Available
Specify the timing start when making an
ISDN call from a Single Line Telephone
(PB/DP), D
term
or Attendant Console, if
required.
•
(1)
(2)
Y=0
50
03-14: 3 sec.-14 sec.
If no data is set, the timing start is not
effective.
(Dialing terminated by entering #.)
Recommended setting is 05 (5 seconds).
D
E
CM76
E
CM08
CM41
F
CM20
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70919 E ISSUE 1 STOCK 151988 ISDN System Manual FEBRUARY 2000 NECAmerica Inc ...
Page 11: ...NEAX2000 IVS2 ISDN System Manual Page vi ND 70919 E Issue 1 0 This page is for your notes ...
Page 211: ...NEAX2000 IVS2 ISDN System Manual Page 200 ND 70919 E Issue 1 0 This page is for your notes ...