CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-24CCTA (CCT)
RUN lamp is not
flashing
Abnormal operation
of CCT card
Confirm the programming data: CM05
Y=0/Y=1, CM07 YY=01.
Check to see if the SENSE switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05 Y=0.
Reset the MB switch.
(Down
→
Up
→
Down)
If the fault cannot be cleared, replace
the card.
LC lamp is not on
Common signaling
channel data link
connection failure
Check the local office line or public network
line.
CRC lamp is on
Bit Error Rate
exceeds the
predetermined
value
Check the receive line and external
equipment.
Replace the remote CCT card.
PCM lamp is on
No PCM signals
arrive from the
distant office
Check to see if the line is correctly
connected to the CCT card.
Plug and unplug the CCT card.
Repeat this two or three times.
FRM lamp is on
Frame Alignment
signals from the
distant office cannot
be received
Check the receive line and external
equipment.
Replace the remote CCT card.
RMT lamp is on
Frame Alignment
signals cannot be
sent to the remote
PBX
Check the transmission line and
external equipment.
Replace the CCT card.
AIS lamp is on
Remote PBX is in
local loop-back
state
Check the switch settings of the remote
CCT card.
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT
CONTENT
REMEDIAL ACTION
1
2
3
4
1
2
1
2
1
2
1
2