CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 109
PN-IPTB
(IPT)
[PZ-M567]
LINK lamp is not on
LAN connection
failure
Check to see if the LAN cable is
correctly connected.
Confirm the condition of the LAN
device connected to the IPT.
(ex. Power of HUB)
Confirm whether the MODE switch is
set to 0.
When the fault cannot be cleared
by to
above, set the MODE to 1,
and set the baud (100 Mbps or 10
Mbps) by the SW2-1 switch according
to the LAN device.
If the fault cannot be cleared, replace
the card.
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT
CONTENT
REMEDIAL ACTION