CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 115
PN-2CSIA
(CSI)
[For North
America/
Latin America]
OPE lamp is not on
D-Channel link is
not connected
between CSH and
CSI
Confirm the programming data: CM06
YY=10.
Confirm if the corresponding CSH card
is removed.
If the fault cannot be cleared, replace
the card.
B00-B12 lamp is
flashing
ZT is not connected
to the
corresponding
circuit No.
Confirm the programming data: CM06,
CM10, CMAD.
Confirm cable connection and the
power switch of the corresponding ZT.
Confirm if the corresponding ZT is in
make-busy status.
PN-2CSIA-A
(CSI)
[For Australia/
Others]
OPE lamp is not on
D-Channel link is
not connected
between CSH and
CSI
Confirm the programming data: CM06
YY=10
Confirm if the corresponding CSH card
is removed.
If the fault cannot be cleared, replace
the card.
B00-B12 lamp is
flashing
CS is not connected
to the
corresponding
circuit No.
Confirm the programming data: CM06,
CM10, CMAD.
Confirm cable connection and the
power switch of the corresponding CS.
Confirm if the corresponding CS is in
make-busy status.
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT
CONTENT
REMEDIAL ACTION
1
2
3
1
2
3
1
2
3
1
2
3