CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 117
PN-32IPLA
(IPELC)
RUN lamp is not
flashing
Abnormal operation
of IPELC card
Confirm whether the MODE switch is
set to “0”, “3”, or “4”.
0: Auto Negotiation ON
(Recommended)
3: Auto Negotiation OFF
(10 Mbps fixed)
4: Auto Negotiation OFF
(100 Mbps fixed)
Confirm the programming data: CM0A.
Reset the MB switch.
(Down
→
Up
→
Down)
If the fault cannot be cleared, replace
the card.
RUN lamp is
flashing rapidly
Communication
error with MP/FP
Confirm the programming data: CM0A.
Check to see if the BUS cable between
each PIM is properly connected.
Reset the MB switch.
(Down
→
Up
→
Down)
If the fault cannot be cleared, replace
the card.
PN-32IPLA
(IPELC)
[PZ-M571]
LINK lamp is not on
LAN connection
failure
Check to see if the LAN cable is
correctly connected.
Confirm the condition of the LAN
device (such as power of the HUB)
connected to the IPELC.
Confirm whether the MODE switch is
set to “0”.
If the fault cannot be cleared, replace
the card.
PN-M03
(M03)
OPE lamp is not
on
Abnormal
connection with the
DPC
Confirm the connection with DPC card.
If the fault cannot be cleared, replace
the card.
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT
CONTENT
REMEDIAL ACTION
1
2
3
4
1
2
3
4
1
2
3
4
1
2