CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 127
After dialing the first digit, Dial
Tone from the distant office is
not disconnected.
(1) Appropriate signal (DP/DTMF) to
distant office is transmitted.
• System Data Programming for DP
signal: CM35 YY=01, 13, 23, 25,
45
• System Data Programming for
DTMF signal: CM35 YY=01, 13,
24, 26, 46
(2) System Data Programming for
Numbering Plan: CM20>A100-
A163,
CM20>A200-A231,
CM22, CM23, CM26
(1) Trunk card
(2) FP card
(3) MP card
C
END
CHECK
REPLACE