CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 129
No Dial Tone Connection on
Tie Line Incoming Call (only for
the 2nd dial tone system)
(1) In case all Tie Line Trunks fail, check
if DTMF Receivers for Tie Line
Incoming Call are installed (only
when the signal kind of the trunk is
DTMF).
In case of ODT card
(1) System Data Programming for the
trunk: CM35 YY=00, 09, 10
(2) Disconnect trunk from the line on
the MDF.
(3) To perform a Loop Back Test, make
a back to back connect of the trunk
and another trunk within the system
at the MDF.
(4) If Dial Tone is returned when the call
is terminated to the original trunk,
there is a problem with the distant
office, the Carrier Equipment, or the
line.
(5) If not, check for trouble with wiring
on the MDF and the trunk card.
(1) Trunk card
A
B
CHECK
CHECK
~
MDF
DT
ODT
ODT
E
M
E
M
REPLACE