CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
(2)
Display Format for users with MATWorX or MATWorX Studio:
Fault information is available via MATWorX or MATWorX Studio. The fault information is
displayed in the order that faults occur. For additional information, please consult the Online
Help included with MATWorX and MATWorX Studio.
Service Conditions
(1)
Print out of fault information is possible through the printer connected to the MAT.
(2)
A maximum of 64 faults can be stored. If the stored information exceeds 64 faults, the
storing method (either overwriting new data or not storing new data) can be selected by
CM08 >451.
(3)
For providing external alarm indication, equipment such as an Alarm Display Panel must be
installed. External alarm indication is provided using a contact to ground at the main
distribution frame. One contact is needed for minor alarms, and one contact is needed for
major alarms.
(4)
The alarm kind (Major Alarm, Minor Alarm or No Alarm Indication) can be programmed by
CMEA Y=2 or set by Fault Storage Add-In of MAT for each fault kind.
Programming Procedure
(1)
To set the fault information storage from the CAT/MAT by Command Operation:
DESCRIPTION
DATA
Enable the fault information storage
feature.
(1)
(2)
450
1
: To provide
Specify the processing at the time of
fault storage memory overflow.
(1)
(2)
451
0
: No fault information is registered
in case of fault memory overflow
1 : Fault information is overwritten in
case of fault memory overflow
Assign which kind of fault information
is stored into the fault information
memory, and which kind of alarm is
indicated.
•
(1)
(2)
Y=2
See the following table.
See the following table.
NOTE:
CMEA programming can be set by the Fault Storage in MAT.
CMEA
CM08
START
A
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Page 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Page 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...