CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 7
DESCRIPTION
DATA
CMEA
A
B
1ST DATA
2ND DATA
DATA
MEANING
DATA
MEANING
Fault Kind: Occurrence
0
3
NONE
External Alarm Kind
0: Fault Memory store/No output
of External Alarm
1: Fault Memory store/External
Alarm is MN alarm
2: Fault Memory store/External
Alarm is MJ alarm
3: Fault Memory store/External
Alarm Kind is determined by
standard data
No Fault Memory store/No
External Alarm output
To assign NONE, enter CCC.
01
System Initialization
04
MP-FP/AP communication
failure
08
FP/AP card down
09
Power failure
12
CS/ZT fault occurred
16
Periodic maintenance
20
DTI line failure
21
DCH/BRT/PRT D-Channel link
connection failure
22
CCH/IPT link connection failure
24
Number of faulty trunks was
more than predetermined
number
[Australia Only]
25
Number of lockout stations was
more than predetermined
number
26
DLC card down
27
Synchronism of DPC missed
28
SMDR output buffer memory
overflow
2B
CS/ZT fault occurred
~