CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
DESCRIPTION
DATA
CMEA
B
C
1ST DATA
2ND DATA
DATA
MEANING
DATA
MEANING
Fault Kind: Restoration
0
3
NONE
External Alarm Kind
0: Fault Memory store/No output
of External Alarm
1: Fault Memory store/External
Alarm is MN alarm
2: Fault Memory store/External
Alarm is MJ alarm
3: Fault Memory store/External
Alarm Kind is determined by
standard data
No Fault Memory store/No
External Alarm output
To assign NONE, enter CCC.
18
FP/AP card returned to normal
condition
19
Power failure returned to normal
condition
30
DTI line returned to normal
condition
31
DCH/BRT/PRT D-Channel link
connection returned to normal
condition
32
CCH/IPT link connection returned
to normal condition
34
Number of faulty trunks was less
than predetermined number
[Australia Only]
35
Number of lockout stations
restored to less than
predetermined number
36
DLC card returned to normal
condition
37
Synchronism of DPC returned to
normal condition
38
SMDR output buffer memory
returned to normal condition
3B
CS/ZT returned to normal