CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Report Scheduling
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 45
FAULT REPORT SCHEDULING
General Description
This feature provides the system to register pre-determined date for periodic maintenance in
advance and notify the information on the day by the PWR card alarm lamp, the D
term
Function
Key Lamp, or External Alarm Display Panel.
Figure 1-3 Fault Report Scheduling Indication
Service Conditions
(1)
The maximum of eight predetermined dates for periodic maintenance, for example, battery
check, are registered by CM43 Y=2 in advance.
(2)
The notification for maintenance is indicated by the alarm lamp (MJ/MN) on the PWR card
or external alarm panel, or the D
term
Function Key Lamp. The D
term
Function Key steady
lights as MJ alarm, or flashes with 60 IPM as MN alarm. The MJ or MN alarm is selected
by CMEA Y=2 in advance.
(3)
The number of D
term
which indicates the periodic maintenance is two in a system.
(4)
The alarm indication can be cleared by CMEA Y=1 from CAT/MAT.
MP
PBX
ALARM PANEL
MJ MN
F
ea
tu
re
4
5
6
G
H
I
J
K L
7
8
9
P
QR
S
T U
V
0
#
OP
E R
1
2
3
A B
C
D
E F
REGISTER THE TIME OF
PERIODIC MAINTENANCE
INDICATE THE LAMP
ON THE SCHEDULED DATE
D
term