CHAPTER 1 MAINTENANCE SERVICE FEATURES
Remote MAT
Programming Procedure
DESCRIPTION
DATA
Assign whether the system clock is set
when the system clock setting
command is received from the RMAT.
(1) 456
(2) 0
: Not set
1
: To set
Assign whether the fault information is
cleared when the fault information clear
command is received from the RMAT.
(1) 457
(2) 0
: To clear
1
: Not cleared
Assign the station number of the MP
built-in modem.
• YY = 10
(1) 1
(2) X-XXXXXXXX:Station No.
Assign the function of analog data
station to the required modem station
number.
• YY = 07
(1) X-XXXXXXXX:Station No.
(2) 0 : Data station
Specify the recall interval timer of the
MP built-in modem.
(1) 69
(2) 45-99: 180 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is
304 sec.
Specify the number of times for recall
from the MP built-in modem.
(1) 19
(2) 01-09: Number of times
If no data is set, the default setting is
04.
Allocate the memory area for the fault
information reporting from the MP
built-in modem.
(1) 67
(2) XXX YYY
XXX: 000-299: Starting Memory Slot
No.
YYY: 001-300: Number of Slots to
be assigned in Block
NOTE:
Assign more than two slots.
CM08
START
CM40
CM13
A
CM41
CM42
CM71