CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 77
04
MP-FP/AP
communication failure
3: XX XX XX XX
Communication Failure Kind
00: Overflow of data sending
buffer to the
FP/AP
01: Invalid data received from
FP/AP
Number of communication
failures
FP/AP Number
00-03, 17-19:
FP No. 0-3,
17-19
04-15, 20-31:
AP No. 4-15,
20-31
Replace the corresponding FP or
AP card indicated in the FP/AP
Number.
08
FP/AP card down
3: XX XX XX XX
FP/AP Number
00-03, 17-19:FP No. 0-3,
17-19
04-15, 20-31:AP No. 4-15,
20-31
Replace the corresponding FP or
AP card indicated in the FP/AP
Number.
09
Power failure
3: XX XX XX XX
Power Failure Kind
(See below.)
Power Failure Kind 00: AC input
failure
Check to see if the AC power
source is cut off or the plug is
disconnected.
Power Failure Kind 01: Fuse break
Check for a break in the battery
fuse.
Power Failure Kind 02: PWR alarm
Check the output voltage of
the PWR card.
Replace the PWR card.