CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
12
CS/ZT Fault
occurred
3.
XX XX XXXX
Fault Kind (See below.)
AP No. of CS/ZT fault occurrence
04-15, 20-31
CS/ZT Interface No. of CS/ZT
fault occurrence 000-255
Fault Kind 00: Fault notice from
CS/ZT
No specific action is required.
Fault Kind 01: CS/ZT initial failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 02: CS/ZT condition read
failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 03: CS/ZT condition
unmatch
No specific action is required.
Fault Kind 04: B-Channel condition
unmatch
No specific action is required.
Table 2-3 Remedial Action on Each Fault Kind (Continued)
FAULT
KIND
NUMBER
FAULT CONTENT
FAULT INFORMATION
REMEDIAL ACTION
1
2
3
1
2
3
1
2
1
2
Summary of Contents for NEAX 2000IVS2