NEAX2000
IVS
2
Maintenance Manual
Page 80
ND-70926
(E),
Issue
3.0
CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
12
CS/ZT Fault
occurred
Fault Kind 07:
CS/ZT make busy
failure
Make the CS/ZT Make busy or
Make idle condition by
CME5 Y=3.
Fault Kind 08:
CS/ZT data load
failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 09:
B channel make
busy failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 0A:
CS/ZT operation
parameter change
failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Table 2-3 Remedial Action on Each Fault Kind (Continued)
FAULT
KIND
NUMBER
FAULT CONTENT
FAULT INFORMATION
REMEDIAL ACTION
1
2
1
2
1
2