CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 81
12
CS/ZT Fault
occurred
Fault Kind 0B:
LCCH sending
position failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 0C:
Carrier selection
failure
[North America/
Latin America
Only]
No specific action is required.
Fault Kind 0D:
CS/ZT expansion
data read failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 0E:
CS/ZT expansion
data setting failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.
Fault Kind 0F:
CS/ZT operation
parameter
2 changing
failure
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
Turn ON • OFF the CS/ZT
power switch.