CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 89
03
Ring wire is
grounded
Check to see if the Ring
wire of the cable is
grounded.
Ring wire is
grounded
Check to see if the
Ring wire of the cable is
grounded.
04
LC card is not
mounted
Check to see if the LC
card is properly mounted.
LC card is not
mounted
Check to see if the LC
card is properly mounted.
05
Test busy
No action is required.
Terminal
failure
Replace the terminal with
a known good one and
check to see if the same
failure occurs.
06
DLC card
down
Replace the card with a
known good one and
check to see if the same
failure occurs.
08
Line failure
detect
Replace the terminal with
a known good one and
check to see if the same
failure occurs.
Software Test
01
Idle
No action is required.
Idle
No action is required.
02
Line Lockout
Place the handset of the
station in line lockout back
onto the hookswitch.
Line Lockout
Place the handset of the
station in line lockout back
onto the hookswitch.
Other than 01, 02
Busy
No action is required.
Busy
No action is required.
Table 2-5 Line Status and Remedial Action (Continued)
INDICATED DATA
SINGLE LINE TELEPHONE
D
term
LINE
STATUS
REMEDIAL ACTION
LINE
STATUS
REMEDIAL ACTION
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Page 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Page 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...