CHAPTER 1 GENERAL INFORMATION
System Capacity
NEAX2000 IVS Retrofit System Guide
ND-71075 (E), Issue 1.0
Page 7
NOTE 1: PZ-M537 (EXPMEM) card is required on MP card.
NOTE 2: PN-SC03 (ICH) card is required for expanded capacity.
NOTE 3: PN-SC03-A (CSH) card is required for expanded capacity.
NOTE 4: SPN-SC00 CCH-D (AP) is required.
NOTE 5: ID Codes include Authorization Code, Forced Account Code, and Remote Access to
System (DISA) Code.
NOTE 6: PZ-M537 (EXPMEM) card is required on AP00 card.
NOTE 7: Key Keeper option required to expand above 48 ports.
NOTE 8: Cards assigned to the expanded AP time slot highway must be mounted in PIM0.
Call Forwarding-
Outside Settings
240
240
240
240
240
240
496
496
496
MP Built-in
SMDR Memory
(Calls/Trunks)
128/32
128/32
128/32
256/64
256/64
256/64
1,024/255
1,024/255
1,024/255
AP00 SMDR
Memory
(Calls)
12,000
12,000
12,000
1,600
1,600
1,600
27,000
27,000
27,000
DID Digit
Conversion
Pattern
500
500
500
500
500
500
1,000
1,000
1,000
LCR/Toll
Restriction
Development
Table
64
64
64
256
256
256
LCR Digit
Addition Pattern
Table
50
50
50
256
256
256
Table 1-2 System Capacity
ITEM
FORMER SYSTEM
RETROFIT SYSTEM
48-PORT
PIM
64-PORT
PIM
72-PORT
PIM
48-PORT
PIM
64-PORT
PIM
72-PORT
PIM