CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 13
: External Alarm Kind (MJ/MN/– –)
External Alarm Kind - Minor (MN), Major (MJ) or no alarm (– –: external alarm is not
provided) is programmed by CMEA Y=2. The following table shows the standard data set
by the 2nd data=3 of CMEA Y=2.
32
CCH/IPT link connection returned to normal condition
34
[Australia Only]
Number of faulty trunks was less than predetermined number
35
Number of lockout stations was less than predetermined number
36
DLC card returned to normal condition
37
Synchronism of DPC returned to normal condition
38
SMDR output buffer memory returned to normal condition
3B
CS/ZT returned to normal condition
Table 1-3 Standard Data Set of External Alarm Kind
FAULT KIND
FAULT CONTENT
ALARM KIND
01
System Initialization
MN ALARM
04
MP-FP/AP communication failure
MN ALARM
08
FP/AP card down
MN ALARM
09
Power failure
MJ ALARM
12
CS/ZT fault occurred
– –
16
It is a day for periodic maintenance
– –
18
FP/AP card returned to normal condition
– –
19
Power failure returned to normal condition
– –
20
DTI line failure
MN ALARM
21
DCH/BRT/PRT D-Channel link connection failure
MN ALARM
22
CCH/IPT link connection failure
MN ALARM
Table 1-2 Fault Restoration Kind Number (Continued)
FAULT KIND NUMBER
FAULT RESTORATION CONTENT