NEAX2000
IVS
2
Maintenance Manual
Page 20
ND-70926
(E),
Issue
3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
: Memory Kind
00: Billing memory block
01: Host CPU No. 0 Output Buffer memory block
02: Host CPU No. 1 Output Buffer memory block
03: Automatic Print Buffer memory block
04: Notice of the rest of memory block numbers in the system
05: CCIS Output Buffer memory block
06: CS report Traffic Data Memory block
: Overflow Kind
When setting CMD000>126:0
00: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
01: Memory overflowed
When setting CMD000>126:1
01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
For memory kind 04, regardless of CMD000>126
01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
: Fault Kind
00: CS/ZT connection down
01: CS/ZT carrier has no space
: AP No. of CS/ZT fault occurred 04-15, 20-31
: CS/ZT Interface No. of CS/ZT fault occurred 000-255
: Fault Restoration Kind
00: CS/ZT connection returned
01: CS/ZT carrier has space
: AP No. returned to normal condition
: CS/ZT Interface No. returned to normal condition